<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ecopower Group &#187; Case Studies</title>
	<atom:link href="http://www.ecopowergroup.com.au/category/casestudies/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.ecopowergroup.com.au</link>
	<description>Ecopower Group</description>
	<lastBuildDate>Tue, 08 Dec 2015 22:53:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.32</generator>
	<item>
		<title>Hybrid Solar System Using Hy-Tech in Park Orchards</title>
		<link>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-park-orchards/</link>
		<comments>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-park-orchards/#comments</comments>
		<pubDate>Wed, 29 Apr 2015 03:47:35 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Case Studies]]></category>

		<guid isPermaLink="false">http://www.ecopowergroup.com.au/new/?p=253</guid>
		<description><![CDATA[<p>The post <a rel="nofollow" href="http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-park-orchards/">Hybrid Solar System Using Hy-Tech in Park Orchards</a> appeared first on <a rel="nofollow" href="http://www.ecopowergroup.com.au">Ecopower Group</a>.</p>
]]></description>
				<content:encoded><![CDATA[
	<div id="fws_603aeee3bfd06" data-bg-mobile-hidden="" class="wpb_row vc_row-fluid standard_section   "  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap"> <div class="row-bg   " style=""></div> </div><div class="col span_12 dark ">
	<div  class="vc_span12 wpb_column column_container col no-extra-padding"  data-padding-pos="all" data-hover-bg="" data-animation="" data-delay="0">
		<div class="wpb_wrapper">
			<div class="img-with-aniamtion-wrap center"><img class="img-with-animation " data-delay="0" data-animation="fade-in" src="http://www.ecopowergroup.com.au/wp-content/uploads/2014/11/off-grid.png" alt="" /></div>
	<div id="fws_603aeee3c0dea" data-bg-mobile-hidden="" class="wpb_row vc_row-fluid standard_section   "  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap"> <div class="row-bg   " style=""></div> </div><div class="col span_12  ">
	<div  class="vc_span12 wpb_column column_container col no-extra-padding"  data-padding-pos="all" data-hover-bg="" data-animation="" data-delay="0">
		<div class="wpb_wrapper">
			<div class="nectar-fancy-ul" data-list-icon="icon-tags" data-animation="true" data-color="accent-color"> 
<h3>Project Details</h3>
<ul>
<li>Location: Park Orchards, Melbourne, VIC</li>
<li>Completed: February 2015</li>
<li>Installation Type: Hy-Tech Residential Hybrid Solar System</li>
<li>System Size:  9kWp solar array</li>
<li>17kWhours usable battery storage</li>
<li>Solar Panels: 36x YINGLI 250W polycrystalline panels</li>
<li>Solar Inverter: 36x ENPHASE 215 microinverters AC coupled to battery storage system</li>
<li>Hybrid Interter: SELECTRONIC SP PRO 5kW  48V Interver / charger</li>
<li>Batteries: 24x 2V 800Ah Neutron Power VISION GEL</li>
</ul>
<p><span id="more-253"></span> </div>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h3>Project Goals</h3>
<p>We were approached with this project by the owner who was going to put in a generator for grid backup. After a short conversation, it was clear to the customer that he could have a Hybrid solar system which would not only backup his property but also reduce his energy consumption from the grid day and night.</p>
<h3>Results</h3>
<p>An AC coupled Enphase microinverter solar system was selected to charge the batteries and supply the house loads due to intermittent shading on the house roof. The solar then fed back to the HY-TECH cabinet to charge the batteries for night time use.</p>
<p>The AC coupled Enphase system allows for easy upgrade of the solar array to enable extra solar charging should it be needed in the future.</p>
<p>This HY-TECH Hybrid system has enabled the customer to combine two requirements they had; Solar and grid back-up, in one neat and tidy fit for purpose solution. Installing the system has meant that there is no need for the refuelling and starting of a Diesel generator when needed except a fully automated solar and battery storage solution that really needs no customer interaction.</p>
<p>The HY-TECH system switches between batteries and grid power when programmed to do so or required without any interruption to power supply.</p>

		</div> 
	</div> 
		</div> 
	</div> 
</div></div>
		</div> 
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-park-orchards/">Hybrid Solar System Using Hy-Tech in Park Orchards</a> appeared first on <a rel="nofollow" href="http://www.ecopowergroup.com.au">Ecopower Group</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-park-orchards/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hybrid Solar System Using Hy-Tech in Pearcedale</title>
		<link>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-pearcedale/</link>
		<comments>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-pearcedale/#comments</comments>
		<pubDate>Wed, 29 Apr 2015 03:28:07 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[Case Studies]]></category>

		<guid isPermaLink="false">http://www.ecopowergroup.com.au/new/?p=236</guid>
		<description><![CDATA[<p>The post <a rel="nofollow" href="http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-pearcedale/">Hybrid Solar System Using Hy-Tech in Pearcedale</a> appeared first on <a rel="nofollow" href="http://www.ecopowergroup.com.au">Ecopower Group</a>.</p>
]]></description>
				<content:encoded><![CDATA[
	<div id="fws_603aeee3c3f0e" data-bg-mobile-hidden="" class="wpb_row vc_row-fluid standard_section   "  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap"> <div class="row-bg   " style=""></div> </div><div class="col span_12 dark ">
	<div  class="vc_span12 wpb_column column_container col no-extra-padding"  data-padding-pos="all" data-hover-bg="" data-animation="" data-delay="0">
		<div class="wpb_wrapper">
			<div class="img-with-aniamtion-wrap left"><img class="img-with-animation " data-delay="0" data-animation="fade-in" src="http://www.ecopowergroup.com.au/wp-content/uploads/2015/04/Screen-Shot-2015-04-29-at-1.26.40-pm.png" alt="" /></div>
	<div id="fws_603aeee3c513d" data-bg-mobile-hidden="" class="wpb_row vc_row-fluid standard_section   "  style="padding-top: 0px; padding-bottom: 0px; "><div class="row-bg-wrap"> <div class="row-bg   " style=""></div> </div><div class="col span_12  ">
	<div  class="vc_span12 wpb_column column_container col no-extra-padding"  data-padding-pos="all" data-hover-bg="" data-animation="" data-delay="0">
		<div class="wpb_wrapper">
			<div class="nectar-fancy-ul" data-list-icon="icon-tags" data-animation="true" data-color="accent-color"> 
<h3>Project Details</h3>
<ul>
<li>Location: Pearcedale, Melbourne VIC</li>
<li>Completed: January 2015</li>
<li>Installation Type: Hy-Tech Residential Hybrid Solar System</li>
<li>System Size:  3kWp solar array</li>
<li>7kWhours usable battery storage</li>
<li>Solar Panels: 12x YINGLI 250W polycrystalline panels</li>
</ul>
<p><span id="more-236"></span> </div>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h3>Project Goals</h3>
<p>The customer came to us as they were building a new house and were interested in Solar. As part of our discussions we educated them on Hybrid solar systems and as a result they elected to go with battery storage. This was to be a bit of tricky design as there was some large loads in the house and to cover them meant a very large battery bank.</p>
<h3>Results</h3>
<p>We decided then to split the switchboards between essential power (general power &amp; light- ing) ran from the hybrid system and solar and the non-essential power (air cons and electric cook top) running straight from mains grid. This enabled us to keep the battery bank size down whilst still covering a majority of the houses general power and lighting 24/7 by the batteries and solar.</p>
<p>A DC coupled solar system was selected to charge the batteries and supply the essential power house loads.</p>
<p>This HY-TECH Hybrid system has enabled the customer to combine Solar and battery storage, in one neat and tidy fit for purpose solution without having to purchase a large expensive battery bank.</p>
<p>The HY-TECH system switches between batteries and grid power when programmed to do so or required without any interruption to pow- er supply.</p>
<p>The HY-TECH system empowers you with a constant and reliable source of power whilst allowing you to take control of your future usage and cost of electricity. This has been particularly helpful at this site as they have lost power twice from the mains grid since the system was installed.</p>

		</div> 
	</div> 
		</div> 
	</div> 
</div></div>
		</div> 
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-pearcedale/">Hybrid Solar System Using Hy-Tech in Pearcedale</a> appeared first on <a rel="nofollow" href="http://www.ecopowergroup.com.au">Ecopower Group</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.ecopowergroup.com.au/hybrid-solar-system-using-hy-tech-in-pearcedale/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
